Vertical air conditioning unit--Element series
Home / Product Center / Air conditioning box / Vertical air conditioning unit--Element series
Vertical air conditioning unit--Element series

Vertical air conditioning unit--Element series

Vertical air conditioning unit--Element series

Dry design with no water accumulation

The water pan has a drainage slope, and the condensed water flows to the drainage outlet

Stainless steel material with thermal insulation on the bottom

  • Product introduction
A 1
V 2
A 3
T 4
100 5, 6, 7
l 8
6 9

1. Hanmer air conditioning box
2. Unit type
3. Product serial number
4. Box plate thickness t-25mm f-50mm
5~7. Nominal air volume (x 100m³/h)
8. Take over direction l-left connect r-right connect
9. Number of coil rows 4-4 rows 6-6 rows 8-8 rows


Unit characteristics

Beautiful appearance, excellent structure, good heat insulation and strength performance

Panel

      ■The panel adopts a double-layer sandwich structure, and special PVC profile is used around the panel, which has excellent heat insulation performance and excellent strength.

      ■The inside of the panel is made of polyurethane foam material with a foaming density of 48kg/m³, which can effectively prevent the transfer of cold energy.

      ■The standard configuration of the panel is internal and external double-layer color steel plates, and materials such as stainless steel plates and salted steel plates can also be selected according to requirements.

      ■There are two choices of panel thickness: 25mm and 50mm.

Excellent sealing, extremely low air leakage rate

Tightness

      ■The frame and panel adopt double sealing, and the sealing material is rubber, which has good elasticity and anti-aging performance.

      ■The sealing rubber is of hollow design with positive and negative pressure follow-up, which has a self-pressing function regardless of positive pressure and negative pressure.

      ■The panel adopts a special aluminum alloy pressing plate and is fixed on the frame by screws, which is firm and reliable.

      ■The air leakage rate of the unit cabinet under 1000Pa standard working conditions is less than 1%.

High Heat Transfer Efficiency

Heat Exchanger

       ■ The heat exchange coil adopts seamless copper tubes and aluminum fins, which are tightly combined by tube expansion.

       ■ There are 4 rows, 6 rows and 8 rows to choose from for the coil standard. The standard of aluminum fin is 2.5mm, and other pitch specifications are also available.

       ■ The selection calculation program can optimize the design of the number of coils, pitch of fins , the number of loops and other parameters under demand conditions to ensure that they meet the actual needs of use.

       ■ The unique coil layout design can ensure thorough drainage and prevent the coil from freezing and cracking to the greatest extent.

Water Tray

       ■There is a condensate pan under the cold coil of the surface, and the dry design with a drainage slope can ensure the smooth discharge of condensate. There is external insulation to prevent condensation 

Smooth operation, low noise

Fan

       ■ Choose domestic or international brand-name products.

       ■ Adopt DIDW double-inlet, double-wide, high-efficiency and low-noise centrifugal fans.

       ■ The fan bearings are brand-name products with self-aligning and self-locking functions. The balance accuracy of wind power reaches G4.0, which greatly extends the service life of the bearing.

       ■ The fan selection software can select high-efficiency fans based on actual operating conditions to ensure that the fans operate under high-efficiency and energy-saving working conditions.

Fan drive

       ■ It adopts a V-belt transmission structure standardly, and uses the belt pulley of the Taper Lock bushing and the imported narrow V-belt. The wide slope structure of the narrow V-belt makes it have higher transmission efficiency and service life.

Motor

       ■ It chooses a well-known brand three-phase squirrel-cage AC induction motor, IP54 protection grade, F grade insulation. The motor  is placed inside the fan standardly and installed on the shock-absorbing bracket together with the fan. The motor is equipped with an adjustment device to adjust the belt tightness.

Universal Surface Mounted Fan Coil--Mulan Series

Universal Surface Mounted Fan Coil--Mulan Series

The new appearance design of the Mulan series WMU ......

Horizontal Concealed Fan Coil--Kangda Series

Horizontal Concealed Fan Coil--Kangda Series

The fan-coil unit is mainly suitable for comfortab......

Horizontal Concealed High Static Pressure Fan Coil--Hengda Series

Horizontal Concealed High Static Pressure Fan Coil--Hengda Series

WA series of high static pressure type surface mou......

Cassette Four Outlet Fan Coil--Cassie Series

Cassette Four Outlet Fan Coil--Cassie Series

Model Air volume 08*170=1360 m³/h The body is li......

Vertical air conditioning unit--Element series

Vertical air conditioning unit--Element series

Vertical air conditioning unit--Element series Dr......

Combined air conditioning unit--Hanfeng Series

Combined air conditioning unit--Hanfeng Series

The frame and panel adopt double sealing, and the ......

Horizontal Air Conditioning Unit--Element Series

Horizontal Air Conditioning Unit--Element Series

The base of the box section is equipped with dual-......

Hanging Air Conditioning Box--Element Series

Hanging Air Conditioning Box--Element Series

Facing the wind inlet side of the coil (wind blow......

SWA series silent ultra-thin household fan coil

SWA series silent ultra-thin household fan coil

SWAE series mute ultra-thin household fan coil uni......

Write your message

*We respect your confidentiality and protection of all information.